Water-based Fan Coils for Hotels and Hospitality
  • Water-based Fan Coils for Hotels and Hospitality
  • Water-based Fan Coils for Hotels and Hospitality

Water-based Cassette Fan Coils: The Ideal Climate Solution for Hotel

In the hospitality industry, guest satisfaction is paramount. Water-based fan coils offer the following benefits for hotels:

  • Silent Operation: Ensure quiet, comfortable stays with minimal noise disturbances.
  • Energy Efficiency: Reduce your energy bills while providing guests with the ideal temperature.
  • Compact Design: Maximize room space by installing ceiling-mounted cassette fan coils that don't compromise comfort.
  • Water-based Fan Coils for Hotels and Hospitality
  • Description

  • Service

  • Company Profile



Why Hotels Prefer Water-based Fan Coil Systems

In the hospitality industry, guest satisfaction is paramount. Water-based fan coils offer the following benefits for hotels:

  • Silent Operation: Ensure quiet, comfortable stays with minimal noise disturbances.
  • Energy Efficiency: Reduce your energy bills while providing guests with the ideal temperature.
  • Compact Design: Maximize room space by installing ceiling-mounted cassette fan coils that don't compromise comfort.

How to Choose the Right Fan Coil for Your Hotel

Step 1 - Determine Your Load Requirements

Calculate the heating or cooling load for each room or the entire hotel. For example, a hotel room with 50m² and a cooling load of 340W per m² will require:

        Cooling load = 50 m² * 340 W/m² = 17,000 W (or 17 kW)
    

Step 2 - Model Selection

For cooling requirements of 17 kW, a unit like FP-136 offers 4.635 kW per unit. In this case, you’d need around 4 units.

Model Cooling Capacity (kW) Air Flow (m³/h) Noise Level (dB)
FP-136 4.635 1360 46

Step 3 - Energy Efficiency Consideration

To calculate energy consumption, consider how long the system will run per day and the average energy use over time. For the FP-136, with 126W power input:

        Annual Energy Use = 126 W * 1,000 hours = 126 kWh/year
    

Next Step: Speak with Our Experts for a Customized Solution!

Ready to improve your hotel's climate control? Get in touch with our team for a tailored solution that meets your specific needs and budget.

FAQ:

  • How do water-based fan coils work in hotel rooms? These systems use water as the heat transfer medium, ensuring efficient cooling and heating. They are installed in the ceiling, which saves space and reduces noise.
  • How long does it take to install these systems in a hotel? Installation typically takes 1-2 days per room, depending on the size of the hotel and the complexity of the installation.
Baoding Yesncer Heating & Cooling Equipment Manufacturing Co., Ltd. is a technology enterprise specializing in technology innovation of the central air-conditioning terminal production and use, located in the ancient city of Baoding, near to the national-level Xiong'an New District with convenient transportation and unlimited potential. The main products include: central air conditioner terminal such as horizontal concealed fan coil, universal mounted fan coil, ultra-thin fan coil, 4-way cassette fan coil and basic air conditioner such as domestic air conditioner, air source heat pump, heat pump, hot air blower, hydraulic module, etc. Research and development technical force: We have a air conditioning box, wind disk and main engine research and development design technical team with more than 10 years experience and the software for coil and fan selection. Own production and inspection equipment: Sheet metal production equipment: CNC turret punch press, CNC shearing machine, CNC bending machine, etc. Coil production equipment: high-speed punching machine, tube expanding machine, pipe bending machine, copper pipe straightening cutting machine, etc. Panel production equipment: rice gold opener, high pressure foaming machine, laminating machine, etc. Assembly production line: fan coil unit assembly line, air handling unit assembly line, etc. Test equipment: test room, electrical safety monitoring equipment, air handling unit air volume test bench, coil pressure test equipment, etc. From 100% incoming inspection of important components to 100% product safety inspection, Yesncer implement programmed assembly line operation and strictly control quality in every process. Whats more, Yesncer set up the minus 25 degrees enthalpy difference laboratory for ensuring each product can run stably and normally. Guaranteed delivery time: Advanced ERP management system is applied to help us complete the production plan smoothly. Yesncer is professional and dedicated to the R&D, design and production of air handling equipment, of which appearance design has obtained the national patent certification and safety performance passed Hefei General Machinery Research Institute and Beijing National Air Conditioning Testing Center's test. We can provide reliable guarantee for your production or life and high quality and convenient service for the maintenance of air conditioning. Our target: To be the expert of designing and manufacturing high quality air handling equipment. We uphold the concept that quality is our life and professional and efficient and meticulous service is our eternal pursuit. Yesncer's vision: To meet the needs of people's comfortable life by providing high-tech, green, energy-saving and environment-friendly HAVC products. Yesncer's mission: To create a global air-conditioning terminal matching and machining center. We have the first-class evaporator, condenser and sheet metal processing equipment. Self-developed control system is more intimate that is to say we master the core technology. We can supply OEM service or air conditioning matching solution for customer

Download

Leave a message
FirstName*
Email*
Mobile
Message*
Nous utilisons des Cookie pour améliorer votre expérience en ligne. En poursuivant votre navigation sur ce site, nous supposons que vous acceptez notre utilisation des Cookie.